Access the full technical dossier for the BP360C series, featuring IP66 protection and high-burst overload architecture.
BP360C | 18kW Tactical Power Station: Flicker-Free Energy for Production
High-Burst Overload Architecture
500% Peak Surge | 200ms (Initial Inrush)
250% Overload | 15s (Motor Stabilization)
200% Overload | 100s (Heavy Handling)
150% Overload | 600s (Extended Delivery)
Safety & Protection System
Cell-Level Monitoring
Real-time tracking of voltage (3.65V overcharge / 2.75V over-discharge thresholds) and temperature.
Short Circuit Response
Active circuit interruption in less than 200μs.
Active Fault Isolation & Lockout
Cumulative short-circuits exceeding 80 cycles within 15 seconds trigger a system lockout, requiring manual restart.
Tactical Physical Intervention
Dedicated Emergency Stop Button for immediate physical disconnection of output.
Environmental Range
Functional discharge range from -20°C to 45°C; operational in high-humidity (up to 95%) non-condensing environments.
Technical Specifications
| Battery Type | LiFePO4 |
| AC Waveform | Pure Sine Wave |
| Capacity | 3072Wh |
| Rated Output Power | 3600W |
| 150% overload | Operation for 600s possible |
| 200% overload | Operation for 100s possible |
| 250% overload | Operation for 15s possible |
| Peak power | 18000W |
| AC Output | 100V/120V/230V/240V |
| Max.PV Input Power | 600W 12V~60V 10A |
| Max.AC Input Power | 860W |
| Charging Time | ~3Hrs(AC) ~5.5Hrs(PV) |
| Size | 665*364*687mm |
| Weight | About 68KG |
| Protection rating | IP66 |
| Noise emissions | <35 dB(A) |
| Charging Temperature Range | 0℃~45℃ |
| Discharging Temperature Range | -20℃~45℃ |
FAQ
Q: Can the unit start a 15A high-torque circular saw?
A: Yes. The BP360C supports a 250% overload for 15 seconds, accommodating the inrush current typical of 15A industrial motors.
Q: How does the unit handle short circuits?
A: The BMS detects short circuits within 200μs. After 80 cumulative cycles, the system enters a protection lock state requiring a manual restart.
Q: Is the unit suitable for outdoor disaster relief?
A: The unit is IP66-rated and operational from -20°C, providing ingress protection against heavy rain and dust.